722500 – Maintenance

Relubrication and Maintenance of the 722500 Series

  1. Lubricants

    • Bearings must be lubricated with Universal Bearing Grease NLGI 2 EP2, suitable for most applications.

    • Temperature range: –20 °C to +120 °C.

    • For low temperatures: use low-viscosity grease.

    • For operation above 100 °C: use high-temperature grease.

  2. Relubrication

    • Relubricate bearings regularly to maintain performance.

    • Relubrication interval depends on load and operating time.

    • Check the grease level frequently to ensure proper lubrication.

    • Insufficient lubrication may cause overheating and wear.

  3. Cleaning and inspection

    • Inspect bearings regularly for wear, damage, or contamination in the grease.

    • Verify that the bearing rotates freely.

    • Clean during inspection with a clean, dry cloth.

    • Do not use aggressive cleaning agents, as they may damage the bearing.

Operating hours per day1-250 RPM250-500 RPM
500-750 RPM750-1000 RPM1000-1500 RPM1500-2000 RPM2000-2500 RPM2500-3000 RPM
812121075433
16127542211
24105321111
Relubrication depending on temperature and environment:
EnvironmentBearing temperatureRelubrication interval
Clean0-50°C6-10 months
50-65°C1-3 months
65-95°C1-4 weeks
Dirty0-65°C1-4 weeks
65-95°C1-7 days
Humid0-95°C1-7 days